3.17.1 Bodywork may deflect no more than 10mm vertically when a 500N load is applied vertically to it 800mm forward of the front wheel centre line and 795mm from the car centre line. The load will be applied in a downward direction using a 50mm diameter ram and an adapter 300mm long and 150mm wide. Teams must supply the latter when such a test is deemed necessary.